On Fri, Jul 16, 2004 at 01:43:14PM -0400, Doug Koobs wrote:

<snip>

> In my electrician days, I usually used two methods, depending on the
> situation. You can use a ShopVac on one end, and a plastic baggie (called
> a "mouse") tied to a pull string on the other end. Then just suck the
> mouse and pull string through. This works best with PVC conduit, since it
> is generally more airtight than the metal varieties.
>
> You can also use a fish tape, like ths:
> http://www.divineimages.com/prod/it32/303/100/FISH/TAPE/ELECTRICIAN/PULL/WIRES.htm
>
> Just push the fish tape in one end till it pops out the other end. Not
> near as fun as the ShopVac and mouse :)
>
> Of course, you can always put a pull string in the conduit as you are
> initially installing...

Whoa. Never used a shop vac! Of course, we usually installed aluminum
flex, not PVC (this was L.A.). Usually used a fish tape on new installs.
If we had to pull more wires into an existing conduit, we'd disconnect
one of the wires and use _it_ as the "pull cord" (if a fish tape
wouldn't fit through).

Paul
-----------------------------------------------------------------------